240vac Relay With Self Powered Switch

Posted on
240vac Relay With Self Powered Switch 3,4/5 4949 reviews

WebSwitch™ Remote Power Switch, is the ideal IP controlled power strip for remote power control, remote reboot, and automatic reboot of network devices using a standard web-browser.Two, Independent IP Controlled Power OutletsWebSwitch has two power outlets which can be independently controlled over an IP network using a web browser on a computer or smartphone. It is completely self-contained and includes a built-in web server, so no external servers, or monthly subscriptions are required.Remote Power ControlUse WebSwitch as a remote control outlet that provides remote power control and/or automatic reboot of these devices: Servers, computers, routers, and other electrical devices.Automatic Reboot & Remote Reboot DeviceWhen configured for automatic reboot, WebSwitch will periodically ping a designated IP address and wait for a response. If there is no response to the ping, WebSwitch will automatically reboot the powered device in an attempt to restore its normal operation.If automatic reboot isn't configured, manual remote reboot can easily be achieved by a simple press of a button on the device's Control Page.WebSwitch is available in two models, WebSwitch & WebSwitch Plus!WebSwitch Plus™WebSwitch™ Plus provides a more complete solution for remotely controlling servers and monitoring their environment. It includes all of the robust features of the WebSwitch, plus more. Additional features include:. Remote temperature monitoring. Two discrete inputs.

Event scheduling. Logging. Email alertsBoth models are engineered to provide excellent performance for many years while running 24/7. You can be confident in using WebSwitch when your critical applications demand reliability and integrity. WebSwitch Part Numbers (Differences highlighted in green) PART NUMBEROUTPUTSINPUTSPOWER SUPPLYXRDI-WS3-NARelays: 2 (10A 100-240V AC (47-63Hz))N/A100-240V AC (47-63Hz)XRDI-WS3P-NARelays: 2 (10A 100-240V AC (47-63Hz))Digital: 2 (0-5VDC)Temp: 3 (-67°F to 257°F (-55°C to +125°C))100-240V AC (47-63Hz)XRDI-WS3-INRelays: 2 (10A 100-240V AC (47-63Hz))N/A100-240V AC (47-63Hz)XRDI-WS3P-INRelays: 2 (10A 100-240V AC (47-63Hz))Digital: 2 (0-5VDC)Temp: 3 (-67°F to 257°F (-55°C to +125°C))100-240V AC (47-63Hz). Xytronix Research & Design Inc. (ControlByWeb.com), strives to provide the utmost in quality products and customer satisfaction.

240vac Relay With Self Powered Switch

Our return policy is stated below:. Products may be returned within 30 days of purchase date for a full refund of the purchase price (excluding shipping). Items returned within that time frame may be opened, but must be in good, resellable condition and include all components (connectors, cables, etc.) that were shipped with the product(s). Note that orders over $1000 that were purchased using a credit card will be subject to a 5% restocking fee to cover credit card charges. Unopened products that are returned more than 30 days but less than 90 days from date of purchase may be returned for a refund of the purchase price minus a 20% restocking fee. Custom products, special orders, large orders (orders greater than 40 pc), and items that are beyond 90 days from the purchase date may not be returned for a refund.Note: All of our products are fully supported and come with a 5-year warranty.

See for more detail.To obtain a refund for a purchase, contact our to obtain an RMA before shipping.Xytronix Research & Design, Inc.1681 West 2960 SouthNibley, Utah 84321USA.

SIA-C Relays are Dual & Self powered overcurrent and earth fault Protection Relays, that obtein the energy to power itself tanks to STANDARD CURRENT TRANSFORMES on the lines. The SIA-C is a overcurrent protection relay with self powered and dual powered (Self + Auxiliary) models. The relay is self powered using the operating current through three /5 (5VA) or /1 (2.5VA) standard current transformers fitted on the lines.

These transformers are also used to obtain current measurements. Optionally, SIAC relay can be used with auxiliary power supply (24 Vdc, 230 Vac, 48 Vdc or 100-230 Vdc/ac).The equipment can be occasionally supplied by an external battery portable kit (KITCOM). Internal Commissioning battery as optional. (Lithium battery: 20 years lifetime).

501, 50/51, 50N/G1, 50/51N/G, 74TCS, PGC, 502, 50N/G2, CLP, 49, 46, 46BC, 50BF, 74CT, 79, 52, SHB, 49 and 68 protection functions. Specific test menu is provided. Remote communications RS485 Modbus RTU or IEC 60870-5-103. High electromagnetic compatibility.

The installation and subsequent maintenance of batteries is eliminated. 50 Instantaneous Phase Overcurrent50/51 Phase inverse time overcurrent50N/G Neutral instantaneous overcurrent measured/calculated50/51N/G Inverse time neutral overcurrent49T External trip52 Circuit Breaker Monitoring79 Recloser68 Zone selection interblokingCLP Cold Load Pick-up46 Negative Sequence Instant overcurrent49 Thermal Image50BF Circuit Breaker Opening Failure46BC Broken Conductor Detection74CT Phase CT Supervision74TCS Trip Supervision PGCSHB Second Harmonic BlockingPGC Programmable Logic Control. SIA RANGETYPESELF & DUAL POWERED (SELF+AUX)SELF & DUAL POWERED (SELF+AUX)SELF & DUAL POWERED (SELF+AUX)AUXILIARY POWEREDAuxiliary Supply24Vdc110Vac230Vac24-230 Vac/dc24Vdc230Vac48 Vdc110-230 Vac/Vdc24-230 Vac/dcSelf Power Supply3.2A, 6.4A, 12.8A, 25.6A or 51.2Adepending on the CT. (x3)0,07 In (x3)0,1 In (x3)External batteryUSB cable / Power bankUSB cable / Power bankKITCOMUSB cable / Power bankInternal battery√ (.)√√ (.)Consumption0,5 W1,5 W0,5 W1,5 – 2,2 WCTSpecific CTStandard CT (/1A 2VA)Standard CT (/1 2,5VA; /5 5VA)Standard CT 0,5VA50122150N/G22150N10/51N/G11150/51N1SHB1174CT146BC11150BF9T1111CLP11174TCS1Trip Block111168 Zone Selection interbloking11186√√√Programmable LogicV3V3V3V3Counters√√√Commands√√√Sett.

NameEmailCompanyApplicationProtection Functions50 + 50/51 + 50N/G + 50/51N/G + 86 + PLCPhase Measurement 1. In = 1 A; (0,10 – 30,00 A) 5. In = 5 A; (0,50 – 150,00 A)Neutral Measurement 1. In = 1 A; (0,10 – 30,00 A) 5. In = 5 A; (0,50 – 150,00 A) A. In = 0,1 A; (0,01 – 3,00 A) B. In = 0,2 A; (0,02 – 6,00 A)Net Frequency 5.

60 HzPower Supply 0. Self powered 1. Self powered + 230 Vac (Dual) 3.

Self powered + 24 Vdc (Dual) 4. Self powered + 48 Vdc (Dual) 5. Self powered + 85-265 Vac/dc (Dual) A.

Self powered + Commissioning battery B. Self powered + 230 Vac (Dual) + Commissioning battery D. Self powered + 24 Vdc (Dual) + Commissioning battery E. Self powered + 48 Vdc (Dual) + Commissioning battery F.

240v

12 Volt Relay Switches

Self powered + 85-265 Vac/dc (Dual) + Commissioning battery. Additional Functions 0. Striker and with external trip (49T) 2.

Coil and with external trip (49T)4. Striker and 230 Vac adapted external tripCommunications 0. RS232 (Modbus RTU) 1. RS232 (Modbus RTU) + RS485 (Modbus RTU)Inputs and Outputs 0. Trip + 2 Outputs 2. Trip + 2 Outputs + 2 Inputs 3. Trip + 3 OutputsMemory 1.

Non-volatile RAM memory 2. Non-volatile RAM memory + Fast start-upLanguages A. English, Spanish and German B. English, Spanish and Turkish C.

English, Spanish and French D. English, Spanish and Russian. Horizontal Assembly with 1 magnetic indicator C. Horizontal Assembly with 3 magnetic indicatorsD.

Pokemon fire red screenshot. Vertical Assembly with 1 magnetic indicatorE. Vertical Assembly, compact Size with 3 magnetic indicatorsF. Vertical Assembly, compact size with 3 magnetic indicators, Backlit LCD,WithdrawableG. Vertical Assembly, compact size with 1 magnetic indicator, Backlit LCDAdaptation -.

240v Relay Switch

50 + 50/51 + 50N/G + 50/51N/G + 86 + PLC A. + 502 + 50N/G2 + 3 Settings group B. +CLP + 4 Settings groupsThis site is protected by reCAPTCHA and the Googleandapply.